Maesflow Control Software, supplied by FLUIGENT Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/maesflow+software/maesflow+software/pmc11099131-456-15-18
Average 90 stars, based on 1 article reviews
maesflow control software - by Bioz Stars, 2026-09
90/100 stars

Images

Related Articles

Control:

Article Title: Dynamic remodelling of cadherin contacts in embryonic mesenchymal cells during differential cell migration
Article Snippet: .. Pressure was controlled using a Microfluidic Flow Control System and the Maesflow software (Fluigent), and the pipettes were manipulated using PatchStar Micromanipulators and the LinLab2 software (Scientifica). .. A 25 μm Z-stack was acquired every 30 seconds until the cells detached using the Andor Dragonly microscope described above.

Article Title: A Stable Chemokine Gradient Controls Directional Persistence of Migrating Dendritic Cells
Article Snippet: High precision bidirectional flow sensors (Flow Unit; Fluigent) interfaced with Maesflow software (Fluigent) allows for direct feedback control and monitoring of individual flow rates. .. Pressure control was automated by the Maesflow software (Fluigent) using custom-made scripts that set the flow rates from the individual inlet dynamically over time. ..

Article Title: Measuring Thousands of Single-Vesicle Leakage Events Reveals the Mode of Action of Antimicrobial Peptides
Article Snippet: .. The microfluidic flows for all depicted inlets were controlled using the Fluigent MFCS-EZ flow control system (Fluigent S.A, France) and its accompanying MAESFLOW software. .. Inlets were connected to the fluid reservoirs (Micrewtube 0.5 mL, Simport) via a polymer tubing (Tygon microbore tubing, 0.02′′ × 0.06′′, Cole Parmer, U.K.) and a metal connector tip (Gauge 23 blunt end, Intertronics).

Article Title: A Stable Chemokine Gradient Controls Directional Persistence of Migrating Dendritic Cells
Article Snippet: Pressure is precisely controlled via a pneumatic pressure regulator (MFCSTM-EZ; Fluigent). .. High precision bidirectional flow sensors (Flow Unit; Fluigent) interfaced with Maesflow software (Fluigent) allows for direct feedback control and monitoring of individual flow rates. .. Pressure control was automated by the Maesflow software (Fluigent) using custom-made scripts that set the flow rates from the individual inlet dynamically over time.

Software:

Article Title: Dynamic remodelling of cadherin contacts in embryonic mesenchymal cells during differential cell migration
Article Snippet: .. Pressure was controlled using a Microfluidic Flow Control System and the Maesflow software (Fluigent), and the pipettes were manipulated using PatchStar Micromanipulators and the LinLab2 software (Scientifica). .. A 25 μm Z-stack was acquired every 30 seconds until the cells detached using the Andor Dragonly microscope described above.

Article Title: Mechanics of human embryo compaction.
Article Snippet: The intermediate reservoir was connected to a microfluidic pump (Fluigent, MFCS-EZ) delivering negative pressures with a 2.5 Pa resolution. .. The pressure is controlled using Maesflow software (Fluigent). ..

Article Title: Mechanical strengthening of cell-cell adhesion during mouse embryo compaction
Article Snippet: The intermediate reservoirs were connected to a microfluidic pump (Fluigent, Le Kremlin-Bicêtre, France, MFCS-EZ) delivering negative pressures with a 2.5 Pa resolution. .. The pressure was controlled using Maesflow software (Fluigent). ..

Article Title: A Stable Chemokine Gradient Controls Directional Persistence of Migrating Dendritic Cells
Article Snippet: High precision bidirectional flow sensors (Flow Unit; Fluigent) interfaced with Maesflow software (Fluigent) allows for direct feedback control and monitoring of individual flow rates. .. Pressure control was automated by the Maesflow software (Fluigent) using custom-made scripts that set the flow rates from the individual inlet dynamically over time. ..

Article Title: Measuring Thousands of Single-Vesicle Leakage Events Reveals the Mode of Action of Antimicrobial Peptides
Article Snippet: .. The microfluidic flows for all depicted inlets were controlled using the Fluigent MFCS-EZ flow control system (Fluigent S.A, France) and its accompanying MAESFLOW software. .. Inlets were connected to the fluid reservoirs (Micrewtube 0.5 mL, Simport) via a polymer tubing (Tygon microbore tubing, 0.02′′ × 0.06′′, Cole Parmer, U.K.) and a metal connector tip (Gauge 23 blunt end, Intertronics).

Article Title: A Stable Chemokine Gradient Controls Directional Persistence of Migrating Dendritic Cells
Article Snippet: Pressure is precisely controlled via a pneumatic pressure regulator (MFCSTM-EZ; Fluigent). .. High precision bidirectional flow sensors (Flow Unit; Fluigent) interfaced with Maesflow software (Fluigent) allows for direct feedback control and monitoring of individual flow rates. .. Pressure control was automated by the Maesflow software (Fluigent) using custom-made scripts that set the flow rates from the individual inlet dynamically over time.

Article Title: Mechanical strengthening of cell-cell adhesion during mouse embryo compaction
Article Snippet: The intermediate reservoirs are connected to a microfluidic pump (Fluigent, MFCS-EZ) delivering negative pressures with a 2.5 Pa resolution. .. The pressure is controlled using Maesflow software (Fluigent). ..

other:

Article Title: A Stable Chemokine Gradient Controls Directional Persistence of Migrating Dendritic Cells
Article Snippet: Figure Flow rate (μl/min) Configuration Maesflow software (Fluigent) Condition Comment / Reference Upper Inlet Central Inlet Lower Inlet 2 70 10 70 Stable gradient (60 min) 3 70 10 70 Standing wave (t = 60 min), 4A 70 0 10 0 70 70 Stable gradient (t = 0 s), Gradient removal (t ≥ 2 s) 4B 70 0 10 0 70 70 Stable gradient (t = 0 min), Gradient removal (t ≥ 30 min) 4C 70 0 10 70 70 0 Stable gradient (t = 0 s), Uniform CCL19 stimulation (t ≥ 45 min) 5A, B 70 0 10 0 70 70 Stable gradient (t = 0 – 2.5 min), Gradient removal (t = 2.5 – 5.0 min) 5C 70 0 10 0 70 70 Stable gradient (t = 0 – 2.5 min), Gradient removal (t = 2.5 – 5.0 min)



Similar Products

90
FLUIGENT Inc maesflow control software
Maesflow Control Software, supplied by FLUIGENT Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/maesflow+software/maesflow+software/pmc11099131-456-15-18
Average 90 stars, based on 1 article reviews
maesflow control software - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
FLUIGENT Inc maesflow software
Maesflow Software, supplied by FLUIGENT Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/maesflow+software/maesflow+software/pm38693259-418-5-7
Average 90 stars, based on 1 article reviews
maesflow software - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results